SEED Guides Shaft-loads Factors < >

8.5 Size
The size of the component relative to the test piece used in laboratory testing, has a direct effect on the apparent fatigue strength, since the larger the part, the more chances of faults within the structure.

The size factor, Kv, is quantified from a comparison between the volume of the component, V, and the volume of the highly stressed portion of the test piece, Vo.

Kv = {V/Vo} 1/30